Lu'an supply HVAC integrated pump set manufacturer

2020-09-18
 Lu'an supply HVAC integrated pump set manufacturer

supply HVAC integrated pump set Explain the structure of the integrated prefabricated pump station: 1. Outdoor stainless steel control cabinet: manual and automatic. The following control functions can be realized: (1) Daily automatic position, realizing unattended pump station. (2) Two for use and one for standby, mutual standby, automatic switching, high water level working at the same time, automatic fault switching. 2. Crushing grid: the crushing grid is placed at the inlet of the FRP cylinder of the pump station, and the submersible crushing grid is safe and reliable; The supporting guide rail is convenient for maintenance and overhaul. 3. Liquid level sensor: pressure sensor (standard configuration)/floating ball switch/water level electrode is used, and special monitoring relay is provided to realize automatic control operation of pump station liquid level. four HVAC integrated pump set Manufacturer Service platform: built-in service platform for valve and water pump maintenance; Customize platforms in different forms, locations and heights as required.

 Lu'an supply HVAC integrated pump set manufacturer

supply HVAC integrated pump set Talking about why the country should vigorously promote smart water, HVAC integrated pump set Manufacturer How to build a smart pump house? The four ministries and commissions of the country put forward safeguard measures and requirements on improving and improving the construction and management of secondary water supply infrastructure for urban residents to ensure water quality safety, requiring that the construction and management of secondary water supply infrastructure should be improved and improved in all aspects to ensure the scientific planning and construction of secondary water supply infrastructure and promote the systematic operation and maintenance of secondary water supply infrastructure. Promote the formation of a new pattern of secondary water supply infrastructure construction and management with clear rights and responsibilities, professional management and adequate supervision, and solve the water quality safety problem of "one kilometer after the urban water supply".

 Lu'an supply HVAC integrated pump set manufacturer

supply HVAC integrated pump set As the underground installation is adopted, it can be directly installed around the residential area, and because of its small floor area, the characteristics of the whole underground installation will not affect the lives of residents. The harmony and unity with the surrounding environment can be achieved through the landscape control room above the ground. HVAC integrated pump set Manufacturer It is used in places that cannot rely on gravity to discharge sewage by itself. Waste water below the water level of the waterway is collected through the sewage tank, as well as waste water discharged far away from the municipal sewage pipe network and sanitary facilities, and sewage is transported to the sewage pipe network with the help of the sewage pump.

 Lu'an supply HVAC integrated pump set manufacturer

HVAC integrated pump set Manufacturer General provisions: equipment discharging heat, steam or harmful substances, supply HVAC integrated pump set Local exhaust should be adopted. When local ventilation can not be used or local ventilation can not meet the health requirements, it shall be supplemented with all-round ventilation or adopt all-round ventilation. The air distribution design shall be optimized according to the characteristics and changes of pollutants, and the normal operation of local exhaust system shall not be damaged. At the same time, when releasing waste heat, moisture and harmful substances, the ventilation volume in all aspects shall be determined according to the large air volume required. When the quantity of harmful substances cannot be determined, the ventilation volume in all aspects can be determined according to the ventilation frequency. All kinds of pump rooms in the domestic sewage treatment station should adopt natural ventilation. When mechanical ventilation is adopted, indoor air should not be recycled. All pump rooms in the oily sewage treatment station should adopt natural ventilation. When mechanical ventilation is adopted, indoor air should not be recycled, and the ventilator and motor should be explosion-proof and directly connected.

 Lu'an supply HVAC integrated pump set manufacturer

HVAC integrated pump set Manufacturer The integrated prefabricated pump station is a comprehensive urban drainage and water supply device that provides potential energy and pressure energy for water. It is composed of cylinders, pipelines, electromechanical equipment, electrical control and other ancillary facilities, and is scientifically matched, reasonably designed and assembled. Its drainage performance, safety performance and operation reliability directly determine the safety of urban drainage and water supply. supply HVAC integrated pump set The demander's requirements for its performance are also getting higher and higher, so detection is the way to obtain the demander's approval.