The microwave electrodeless ultraviolet sterilization equipment can ensure the sterilization effect and water quality of the effluent. It is a durable and effective sterilization technology. There is no reactivation reaction and no rebound of bacteria, ensuring complete disinfection effect and water quality safety. Compared with other sterilization methods, UV has many obvious advantages, Customized Breeding sterilization and disinfection equipment In particular, unlike chemical fungicides, the ultraviolet sterilizer will not bring toxic substances and residual substances into purified water, Breeding sterilization and disinfection equipment programme The chemical composition, odor and pH value of the fluid will not be changed. This feature is very important in pharmaceutical industry and related industries. The chemical dosage of influent can often change the characteristics of products.

Have you ever thought about whether you need a sterilizer on your water tank? If so, which Z is better? An aquarium scientist's differences between ozone and ultraviolet sterilizers. Ozone is a gas composed of three oxygen atoms, while the oxygen we breathe is composed of two oxygen atoms. This chemical structure makes ozone highly active, Customized Breeding sterilization and disinfection equipment That's why it's such a powerful sterilizer. Breeding sterilization and disinfection equipment programme It is meaningful that the bulb in the UV germicidal lamp is made of quartz, because quartz will not filter out the UV rays. However, water filters light according to its depth. Therefore, the water flow space between the quartz bulb and the external glass or plastic tube is usually only a few millimeters - a thicker space will reduce the intensity of ultraviolet rays and allow bacteria and other microorganisms to survive.

The sterilization principle of the microwave ultraviolet water treatment equipment is mainly to use the irradiation intensity of the ultraviolet lamp, that is, the radiation intensity emitted by the ultraviolet sterilization lamp, which is inversely proportional to the distance of the irradiated disinfectant. Therefore, when the irradiation reaches a certain level, the disinfectant it is exposed to will stay longer, and the closer it is to the sterilization lamp, the better the sterilization effect will be, otherwise, the worse it will be. So, what are the sterilization principles and application characteristics of the submerged microwave ultraviolet water treatment equipment? Now, let's discuss it with you! After absorbing ultraviolet rays, microorganisms will cause some changes in the structure of nucleoprotein molecules in their own cells, resulting in protein denaturation and breakage on the DNA chain, as well as destruction of cross links in DNA molecules, hydration on cytosine and uracil, and even dimers on adenosine, Because dimerization destroys the normal pairing of purine and pyrimidine, it changes the biological activity of DNA. As a result, the metabolism of microorganisms will be hindered, and they cannot proliferate, produce cells and destroy them; Causes the synthesis of proteins and enzymes in bacteria to be blocked, Customized Breeding sterilization and disinfection equipment As a result, the structure and function will be changed and destroyed, which will lead to the death of microorganisms and achieve the purpose of disinfection and sterilization. Experiments have proved that UV is the most bactericidal in the range of 240nm to 280nm, especially when the wavelength is 253.7 μ m, Breeding sterilization and disinfection equipment programme The germicidal effect of ultraviolet radiation is the best. Because a section of C frequency in the ultraviolet ray is very effective in destroying harmful bacteria or viruses. Because UV can kill bacteria, molds, viruses, unicellular algae and other organisms, UV is the preferred equipment for sterilization in the microwave UV water treatment equipment industry.

According to different lamp tubes, ultraviolet sterilization lamps have thermal cathode low-pressure mercury vapor discharge lamps and cathode low-pressure mercury vapor discharge lamps; The hot cathode low-pressure mercury vapor discharge lamps can be divided into straight type, H-type, U-type tube, etc. from the appearance; Customized Breeding sterilization and disinfection equipment For different needs, it can be divided into low (no ozone), ozone, high ozone, etc. The portable microwave electrodeless ultraviolet sterilization equipment can be used for close mobile irradiation, and the ultraviolet lamp suspension irradiation can also be used. Small articles can be irradiated in the ultraviolet disinfection box. Different kinds of microorganisms have different sensitivity to ultraviolet rays. When using ultraviolet rays for disinfection, the radiation dose must be used to reach the radiation dose required to kill the target microorganisms. Breeding sterilization and disinfection equipment programme The product of the irradiation intensity and irradiation time of the ultraviolet lamp used for irradiation dose at the surface of the irradiated object. Therefore, according to the irradiation intensity of the ultraviolet light source, the required irradiation time can be calculated.

According to the source of sewage, sewage microwave ultraviolet water treatment equipment mainly includes production sewage microwave ultraviolet water treatment equipment and domestic sewage microwave ultraviolet water treatment equipment. The former refers to industrial sewage microwave ultraviolet water treatment equipment and hospital sewage microwave ultraviolet water treatment equipment, while domestic sewage mainly refers to sewage generated in daily life, municipal sewage microwave ultraviolet water treatment equipment, etc. Sewage quality includes TSS, namely suspended solids in water, sewage type and proportion, etc. The types of sewage and water quality are different. When choosing ultraviolet sterilization equipment, Customized Breeding sterilization and disinfection equipment It shall be configured differently. Water volume mainly refers to the average flow and peak flow of sewage to be treated. Secondly, consider whether the equipment operation time is 24 hours or intermittent water supply. In addition, Breeding sterilization and disinfection equipment programme In addition, the discharge standards for effluent quality requirements and the bacterial indicators and requirements for sewage inflow and outflow shall be considered, and the number of modules required for the UV sterilization equipment of the sewage microwave UV water treatment equipment, the number of lamps included in the module, and the discharge distance of the module shall be specifically designed. In addition, when selecting equipment, we must first determine the treatment water quantity, water quality, discharge standards and other factors. In the process of model selection, the quality, service life and after-sales service of ultraviolet sterilization equipment should be comprehensively investigated.