The trapezoidal structure made of food grade transparent silica gel and special mold is used to prevent water leakage caused by improper installation. Ultraviolet sterilization equipment programme UV irradiation intensity sensor/UV irradiation intensity monitor: The UV irradiation intensity sensor can monitor the output intensity of the UV disinfection system in real time online, and output mixed signals of 0-5V or 4-20mA for use by the monitor. production Ultraviolet sterilization equipment The ultraviolet radiation intensity monitor receives the signal provided by the sensor, and can set the radiation intensity alarm value and lamp life according to the requirements. Monitor the system in real time to ensure the normal operation of the equipment.

Microwave and ultraviolet water treatment equipment is a special form of material operation, which is a particle flow without connection. Each UV photon with a wavelength of 253.7 nm has an energy of 4.9 eV. When ultraviolet rays irradiate microorganisms, energy transfer and accumulation will occur, and the accumulation results in the inactivation of microorganisms, thus achieving the purpose of disinfection. When bacteria and viruses absorb more than 3600~65000uW/cm2, it has a strong destructive power to the DNA and RNA of bacteria and viruses, and can make bacteria and viruses lose their viability and fecundity, thereby eliminating bacteria and viruses, achieving disinfection and sterilization effect. On the one hand, ultraviolet light can mutate nucleic acids, hinder their replication, transcriptional blockade and protein synthesis; on the other hand, the generation of free radicals can cause photoionization, thus leading to cell death. Ultraviolet sterilization equipment programme The sterilization principle of the microwave ultraviolet water treatment equipment is to use the irradiation intensity of the ultraviolet lamp, that is, the irradiation intensity emitted by the ultraviolet sterilization lamp, which is inversely proportional to the distance of the irradiated disinfectant. production Ultraviolet sterilization equipment When the irradiation intensity is constant, the longer the irradiated disinfectant stays, the closer it is to the germicidal lamp, the better its germicidal effect, and vice versa. With strong destructive power, it can make bacteria and viruses lose their viability and reproduction, and then eliminate bacteria and viruses to achieve disinfection and sterilization effect.

What are the common faults of microwave and ultraviolet water treatment equipment, production Ultraviolet sterilization equipment Leakage in the water pressure drop equipment system, lack of pressure at the inlet of the high-pressure pump, air leakage, water leakage, blockage of the filter element of the precision filter, high-pressure pump fault, etc. may cause the water pressure drop of the equipment. Solution: Overhaul the high-pressure pump and precision filter, and eliminate problems. Ultraviolet sterilization equipment programme The increase of equipment water pressure may be due to the error of high-pressure pump outlet scheduling index and the blockage of the pipeline from high-pressure pump to reverse osmosis equipment. Solution: recover the equipment pressure by dispatching the outlet index of the high-pressure pump and cleaning the pipeline between the high-pressure pump and the reverse osmosis equipment. The decrease in water production of the manufacturers of microwave and ultraviolet water treatment equipment may be due to the lower water temperature, lower water pressure, and pollution and blockage of the reverse osmosis membrane. Solution: recover normal production by adjusting the temperature of raw water and cleaning and replacing the reverse osmosis membrane.

Ultraviolet disinfection belongs to physical instant disinfection technology, which can keep sterile under the condition that the water body is not polluted. When the treated water leaves the disinfection reactor, production Ultraviolet sterilization equipment Some microorganisms killed by ultraviolet light will repair damaged molecules and regenerate bacteria under visible light irradiation, which is called light reactivation. Ultraviolet sterilization equipment programme Some bacteria can also repair themselves under the condition of no light, that is, dark reactivation. According to the current research results, photoreactivation is the main way of most microbial remediation and also the main control target.

Ultraviolet disinfection can ensure sterilization effect and water quality. This is a long-term effective sterilization technology. There is no reactivation reaction and no rebound of flora, ensuring complete disinfection effect and water quality safety. production Ultraviolet sterilization equipment Compared with other sterilization methods, UV has many obvious advantages, especially the difference from chemical disinfectants is that UV sterilizers will not bring toxic substances and residues into pure water, and will not change its chemical composition, odor and pH value. This function is very important in the pharmaceutical industry and related industries. Ultraviolet sterilization equipment programme The chemical dosage of influent often changes the characteristics of the product. It can effectively kill all bacteria and viruses, and inactivate chlorine resistant microorganisms such as Legionella, Escherichia coli and Pseudomonas. Cryptosporidium, amoeba and bacteria.

Microwave electrodeless ultraviolet sterilization equipment can destroy the molecular structure of DNA (deoxyribonucleic acid) or RNA (ribonucleic acid) in the cells of microbial organism by using ultraviolet light of appropriate wavelength, production Ultraviolet sterilization equipment Cause growth cell death and (or) regenerative cell death to achieve the effect of sterilization. The microwave electrodeless ultraviolet sterilization equipment should be one of the equipment in the system before the water returns to the aquarium. It should be preceded by biological and mechanical filters, as well as any chemical filters or heat exchangers in the system. Ultraviolet sterilization equipment programme Follow the manufacturer's installation instructions. Most devices use hose barb connectors to connect to the appropriate water pump, or are designed to allow additional connectors to be connected as PVC sliding fit or hose barb. To ensure microwave electrodeless ultraviolet sterilization