Yantai New Aquaculture Sterilization Equipment Scheme

2021-10-02
 Yantai New Aquaculture Sterilization Equipment Scheme

Microwave electrodeless ultraviolet sterilization equipment can destroy the molecular structure of DNA (deoxyribonucleic acid) or RNA (ribonucleic acid) in the cells of microbial organism by using ultraviolet light of appropriate wavelength, new type Aquaculture sterilization equipment Cause growth cell death and (or) regenerative cell death to achieve the effect of sterilization. The microwave electrodeless ultraviolet sterilization equipment should be one of the equipment in the system before the water returns to the aquarium. It should be preceded by biological and mechanical filters, as well as any chemical filters or heat exchangers in the system. Aquaculture sterilization equipment programme Follow the manufacturer's installation instructions. Most devices use hose barb connectors to connect to the appropriate water pump, or are designed to allow additional connectors to be connected as PVC sliding fit or hose barb. To ensure microwave electrodeless ultraviolet sterilization

 Yantai New Aquaculture Sterilization Equipment Scheme

1. If linear installation is required, please use the installation method of low water inlet and high water outlet to slow down the water flow rate and increase the effect of ultraviolet radiation. 2. When working, Aquaculture sterilization equipment programme Do not look directly into your eyes with an ultraviolet lamp. When the equipment is open, repeated opening and closing will seriously affect the service life of the lamp. 3. If the water flow is too fast, please install current limiting and pressure limiting devices. 4. If the turbidity of raw water exceeds 5 degrees, a prefilter should be installed to ensure ultraviolet sterilization. 5. Please take out the quartz sleeve every time. new type Aquaculture sterilization equipment After using the disinfection lamp for two to three months, check the surface for dirt to determine the next time to clean the surface of the quartz sleeve.

 Yantai New Aquaculture Sterilization Equipment Scheme

Microwave electrodeless ultraviolet sterilization equipment focuses on "ultraviolet". Through the role of ultraviolet, it mainly uses 254 nm ultraviolet light. This wavelength of ultraviolet light, even with a small amount of ultraviolet radiation, can damage a cell's life core - DNA, thus preventing cell regeneration, new type Aquaculture sterilization equipment Loss of regenerative capacity makes bacteria harmless, thus achieving sterilization effect. In order to ensure that no microorganisms can be detected in the product, ultraviolet disinfection can be used, which is a non chemical disinfection method, Aquaculture sterilization equipment programme Ultraviolet rays will not introduce toxins or residues in water, and will not change the chemical composition, taste, odor/PH value of the liquid to be disinfected.

 Yantai New Aquaculture Sterilization Equipment Scheme

After years of development, microwave electrodeless UV sterilization equipment has been widely used in drinking water, food, beverages, electronic products, chemicals, medicine, sewage microwave UV water treatment equipment and other fields. Aquaculture sterilization equipment programme High intensity odorless UV germicidal lamp is used to simplify the special stainless steel inner wall, so that the pretreated water has enough UV when passing through the UV. new type Aquaculture sterilization equipment Irradiation has good sterilization effect. In addition, it has the advantages of simplicity, convenience, broad-spectrum, no secondary pollution, convenient management and automation.

 Yantai New Aquaculture Sterilization Equipment Scheme

1. The welding of equipment shell and framework shall be firm without obvious deformation or burn through defects. 2. The equipment surface shall be evenly sprayed with the same color, and the surface shall be free of flow marks, bubbles, paint leakage and peeling. 3. The appearance of the equipment shall be neat and beautiful without obvious hammer marks and unevenness. The panel instruments, switches, indicator lights and labels shall be installed firmly and correctly. In order to ensure the stability of the equipment, we need to replace the lamp regularly, new type Aquaculture sterilization equipment The imported lamp should be replaced after 9000 hours of continuous service or one year to ensure a high disinfection rate. Aquaculture sterilization equipment programme When replacing the lamp tube, first pull out the power socket of the lamp tube, pull out the lamp tube, then carefully insert the cleaned new lamp tube into the sterilizer, install the gasket, check for water leakage, and then plug in the power supply. Be careful not to touch the quartz glass of the new lamp tube with your fingers, otherwise the disinfection effect will be affected due to stains.

 Yantai New Aquaculture Sterilization Equipment Scheme

What are the common faults of microwave and ultraviolet water treatment equipment, new type Aquaculture sterilization equipment Leakage in the water pressure drop equipment system, lack of pressure at the inlet of the high-pressure pump, air leakage, water leakage, blockage of the filter element of the precision filter, high-pressure pump fault, etc. may cause the water pressure drop of the equipment. Solution: Overhaul the high-pressure pump and precision filter, and eliminate problems. Aquaculture sterilization equipment programme The increase of equipment water pressure may be due to the error of high-pressure pump outlet scheduling index and the blockage of the pipeline from high-pressure pump to reverse osmosis equipment. Solution: recover the equipment pressure by dispatching the outlet index of the high-pressure pump and cleaning the pipeline between the high-pressure pump and the reverse osmosis equipment. The decrease in water production of the manufacturers of microwave and ultraviolet water treatment equipment may be due to the lower water temperature, lower water pressure, and pollution and blockage of the reverse osmosis membrane. Solution: recover normal production by adjusting the temperature of raw water and cleaning and replacing the reverse osmosis membrane.