新上海sh419

 Microwave ultraviolet water treatment equipment
Your current location: home page > Hot information

contact us Contact Us

Shandong Dehai Weilang Energy Equipment Co., Ltd

Contact: Mr. Wang

Tel.: 13001718597

Tel.: 0531-88551699

Email: [email protected]

Address: No. 6, Weihua West Road, Shizhong District, Jinan

Wenzhou Customized Microwave Liquid Sterilization Factory

2023-09-11
 Wenzhou Customized Microwave Liquid Sterilization Factory

When installing microwave and ultraviolet water treatment equipment, the command must be strengthened to prevent equipment collision. Customized Microwave liquid sterilization And these important devices are assigned special management, storage and storage problems. Microwave liquid sterilization manufactor In the field of construction, prepare sufficient quantity and quality of fire-fighting tools for inspection, and require them to use only in case of fire. The construction personnel entering the site shall be checked and wear qualified protective equipment, such as safety helmet, because personal safety is very important.

 Wenzhou Customized Microwave Liquid Sterilization Factory

The technology of microwave ultraviolet water treatment equipment is to use double layer ultrafiltration membrane for microwave ultraviolet water treatment equipment, or combine ultrafiltration membrane and reverse osmosis filtration membrane for application. Microwave liquid sterilization manufactor When the manufacturer of microwave ultraviolet water treatment equipment applies external pressure on the concentrated solution side, the penetration speed will decrease. When the pressure increases to a certain value, the penetration process will stop and the so-called penetration balance will be reached. The external pressure under the balance condition is called the penetration pressure. When the pressure on the concentrated solution side continues to increase, that is, when the applied pressure is greater than the penetration pressure, The solvent of purified water equipment will reverse its original soaking direction and enter the dilute solution side from the concentrated solution side through the semi permeable membrane, Customized Microwave liquid sterilization This phenomenon is called reverse osmosis. For a long time, it will not only affect the effluent quality of the equipment, but also lead to the fouling of the reverse osmosis membrane of the main components of the equipment, resulting in the small output of the pure water equipment, the substandard effluent quality, or the equipment can not be used. In order to ensure the continuous and safe operation of pure water equipment, the maintenance of pure water equipment is very important.

 Wenzhou Customized Microwave Liquid Sterilization Factory

Activated carbon adsorption and catalytic combustion equipment is a common volatile organic waste gas treatment equipment. It is energy-saving, environmental protection, no secondary pollution, and high purification efficiency. It is a very good equipment for VOC waste gas treatment. Generally, the main composition of activated carbon adsorption catalytic combustion equipment is as follows: Pretreatment equipment: since honeycomb activated carbon adsorption requires specific conditions such as temperature, humidity and cleanliness, it is necessary to treat the organic waste gas with different characteristics before entering the activated carbon adsorption. The organic waste gas containing more dust particles needs to be filtered. The waste gas with a temperature greater than 45 ℃ needs to be cooled, and the waste gas containing a large number of water mist particles needs to be separated and filtered. Activated carbon adsorption bed: it can absorb organic waste gas by taking advantage of the porous physical characteristics of activated carbon. The design of the adsorption bed follows the law of two-phase adsorption curve. Only by combining the amount of activated carbon and calculating the cross section wind speed and retention time of activated carbon adsorption can the adsorption efficiency meet the design requirements and meet the emission standards. The box is in negative pressure state during equipment operation, and it is required to be air tight. The desorption temperature of the box is between 70-100 ℃ during the desorption process, and the heat preservation is generally 50mm considering the energy saving and safety factors. Ensure that the temperature of the outer wall of the box is not higher than the normal temperature by 15 ℃. Main exhaust fan: as the main power of the equipment, the exhaust fan guides the air to move according to the specified process. The fan can be selected accurately only when it is stable and reliable, and the resistance calculation of the system is accurate. The operation of the fan will produce noise, and the high-power fan needs to be equipped with a sound insulation room. Attention shall be paid to the design that the wind speed at the air outlet shall not be too high. Catalytic combustion equipment: after the system has operated for a period of time, the activated carbon needs to be regenerated after adsorption saturation to restore the adsorption activity of the activated carbon. The organic waste gas is concentrated in the activated carbon. After the organic matter is separated from the activated carbon layer at low temperature, it is decomposed into water and carbon dioxide at about 300 ℃ through the action of catalyst. At the same time, the energy is released. The energy is replaced by the heat exchange device to maintain the energy of spontaneous combustion of the equipment. For a single activated carbon adsorption bed, the desorption time is 2-2.5 hours. The set time of activated carbon adsorption box is automatically switched to desorption regularly. The service life of the ceramic honeycomb noble metal catalyst loaded inside is 8000 hours. The whole desorption system adopts multi-point temperature control to ensure the stability of desorption effect. The selection of organic waste gas catalyst is the core of this equipment. Valve switching system: valves include adsorption system valve, desorption system valve, cooling and emergency discharge valve. The three types of valves are required to be timely and accordingly to ensure that the air leakage rate is less than 2%. The conventional galvanized sheet air valve in the market has air leakage due to unreliable sealing, so it is necessary to select the high temperature resistant air valve with silicone gasket. The temperature is reliable when opening and closing the valve. Due to the temperature of the gas through which the valve passes, it is very easy for conventional plastic electric actuators to age and deform, resulting in ineffective execution. Generally, long rod actuators are used.

 Wenzhou Customized Microwave Liquid Sterilization Factory

Microwave and ultraviolet water treatment equipment is a special form of material operation, which is a particle flow without connection. Each UV photon with a wavelength of 253.7 nm has an energy of 4.9 eV. When ultraviolet rays irradiate microorganisms, energy transfer and accumulation will occur, and the accumulation results in the inactivation of microorganisms, thus achieving the purpose of disinfection. When bacteria and viruses absorb more than 3600~65000uW/cm2, it has a strong destructive power to the DNA and RNA of bacteria and viruses, and can make bacteria and viruses lose their viability and fecundity, thereby eliminating bacteria and viruses, achieving disinfection and sterilization effect. On the one hand, ultraviolet light can mutate nucleic acids, hinder their replication, transcriptional blockade and protein synthesis; on the other hand, the generation of free radicals can cause photoionization, thus leading to cell death. Microwave liquid sterilization manufactor The sterilization principle of the microwave ultraviolet water treatment equipment is to use the irradiation intensity of the ultraviolet lamp, that is, the irradiation intensity emitted by the ultraviolet sterilization lamp, which is inversely proportional to the distance of the irradiated disinfectant. Customized Microwave liquid sterilization When the irradiation intensity is constant, the longer the irradiated disinfectant stays, the closer it is to the germicidal lamp, the better its germicidal effect, and vice versa. With strong destructive power, it can make bacteria and viruses lose their viability and reproduction, and then eliminate bacteria and viruses to achieve disinfection and sterilization effect.

Share to