Have you ever thought about whether you need a sterilizer on your water tank? If so, which Z is better? An aquarium scientist's differences between ozone and ultraviolet sterilizers. Ozone is a gas composed of three oxygen atoms, while the oxygen we breathe is composed of two oxygen atoms. This chemical structure makes ozone highly active, Customized UV photo oxygen microwave deodorization equipment That's why it's such a powerful sterilizer. UV photo oxygen microwave deodorization equipment programme It is meaningful that the bulb in the UV germicidal lamp is made of quartz, because quartz will not filter out the UV rays. However, water filters light according to its depth. Therefore, the water flow space between the quartz bulb and the external glass or plastic tube is usually only a few millimeters - a thicker space will reduce the intensity of ultraviolet rays and allow bacteria and other microorganisms to survive.

What are the common faults of microwave and ultraviolet water treatment equipment, Customized UV photo oxygen microwave deodorization equipment Leakage in the water pressure drop equipment system, lack of pressure at the inlet of the high-pressure pump, air leakage, water leakage, blockage of the filter element of the precision filter, high-pressure pump fault, etc. may cause the water pressure drop of the equipment. Solution: Overhaul the high-pressure pump and precision filter, and eliminate problems. UV photo oxygen microwave deodorization equipment programme The increase of equipment water pressure may be due to the error of high-pressure pump outlet scheduling index and the blockage of the pipeline from high-pressure pump to reverse osmosis equipment. Solution: recover the equipment pressure by dispatching the outlet index of the high-pressure pump and cleaning the pipeline between the high-pressure pump and the reverse osmosis equipment. The decrease in water production of the manufacturers of microwave and ultraviolet water treatment equipment may be due to the lower water temperature, lower water pressure, and pollution and blockage of the reverse osmosis membrane. Solution: recover normal production by adjusting the temperature of raw water and cleaning and replacing the reverse osmosis membrane.

To solve the problem of light reactivation: open the channel to realize underground water outflow, to avoid or reduce the visibility of treated water before entering the pipeline. At the same time, use a dark container containing a sample of test water, Customized UV photo oxygen microwave deodorization equipment It shall be sent for inspection in time to avoid factors such as storage conditions or test time affecting the test results. Improve the light transmittance: adjust the front-end treatment process to reduce the SS mass concentration of water in the UV disinfection device, UV photo oxygen microwave deodorization equipment programme The ultraviolet disinfection I was adjusted to ozone decolorization, which reduced the chromaticity of the influent water to ensure that SS was controlled below 10 mg/L; The front-end technology has been adjusted to strictly control the consumption of PAM and other chemicals, and a defoaming device has been installed at the water inlet of the external disinfection device to reduce the foam content in the water body and increase the light transmittance of the water body.

According to the source of sewage, sewage microwave ultraviolet water treatment equipment mainly includes production sewage microwave ultraviolet water treatment equipment and domestic sewage microwave ultraviolet water treatment equipment. The former refers to industrial sewage microwave ultraviolet water treatment equipment and hospital sewage microwave ultraviolet water treatment equipment, while domestic sewage mainly refers to sewage generated in daily life, municipal sewage microwave ultraviolet water treatment equipment, etc. Sewage quality includes TSS, namely suspended solids in water, sewage type and proportion, etc. The types of sewage and water quality are different. When choosing ultraviolet sterilization equipment, Customized UV photo oxygen microwave deodorization equipment It shall be configured differently. Water volume mainly refers to the average flow and peak flow of sewage to be treated. Secondly, consider whether the equipment operation time is 24 hours or intermittent water supply. In addition, UV photo oxygen microwave deodorization equipment programme In addition, the discharge standards for effluent quality requirements and the bacterial indicators and requirements for sewage inflow and outflow shall be considered, and the number of modules required for the UV sterilization equipment of the sewage microwave UV water treatment equipment, the number of lamps included in the module, and the discharge distance of the module shall be specifically designed. In addition, when selecting equipment, we must first determine the treatment water quantity, water quality, discharge standards and other factors. In the process of model selection, the quality, service life and after-sales service of ultraviolet sterilization equipment should be comprehensively investigated.

Now people pay more attention to health, and the demand for ultraviolet disinfection equipment will be more and more extensive. Customized UV photo oxygen microwave deodorization equipment The UV sterilization equipment is highly integrated, with low maintenance costs, which saves the time and energy of operators without adding any other chemical reagents. UVC ultraviolet ray plays a real role in disinfection equipment, UV photo oxygen microwave deodorization equipment programme The ultraviolet radiation can destroy and change the DNA (deoxyribonucleic acid) structure of microorganisms, so that the bacteria will die immediately or cannot reproduce, so as to achieve the purpose of sterilization.

1. The welding of equipment shell and framework shall be firm without obvious deformation or burn through defects. 2. The equipment surface shall be evenly sprayed with the same color, and the surface shall be free of flow marks, bubbles, paint leakage and peeling. 3. The appearance of the equipment shall be neat and beautiful without obvious hammer marks and unevenness. The panel instruments, switches, indicator lights and labels shall be installed firmly and correctly. In order to ensure the stability of the equipment, we need to replace the lamp regularly, Customized UV photo oxygen microwave deodorization equipment The imported lamp should be replaced after 9000 hours of continuous service or one year to ensure a high disinfection rate. UV photo oxygen microwave deodorization equipment programme When replacing the lamp tube, first pull out the power socket of the lamp tube, pull out the lamp tube, then carefully insert the cleaned new lamp tube into the sterilizer, install the gasket, check for water leakage, and then plug in the power supply. Be careful not to touch the quartz glass of the new lamp tube with your fingers, otherwise the disinfection effect will be affected due to stains.