RCO organic waste gas catalytic combustion purification equipment can effectively purify the environment, pollution, improve labor operating conditions, ensure the health of workers, and the heat emitted can be recycled to reduce production costs. RCO organic waste gas catalytic combustion equipment has perfect system design, complete auxiliary equipment, high purification efficiency and high automation. RCO organic waste gas catalytic combustion equipment RCO organic waste gas catalytic combustion purification device is designed based on two basic principles of adsorption and catalytic combustion, namely adsorption concentration catalytic combustion method. The dedusting equipment adopts the working mode of single bed adsorption purification of organic waste gas and catalytic combustion device regeneration and activation of activated carbon. Firstly, the organic waste gas with low concentration is adsorbed by activated carbon, and the adsorption operation is stopped when it is almost saturated, then the organic matter is desorbed from the activated carbon by hot gas flow to regenerate the activated carbon; The desorbed organic matter has been concentrated (the concentration is dozens of times higher than the original) and sent to the catalytic combustion chamber for catalytic conversion into CO2 and H2O for emission; When the concentration of organic waste gas reaches above 2000ppm, the organic waste gas can maintain spontaneous combustion in the catalytic bed without external heating. Some of the burned tail gas is discharged into the atmosphere, and most of it is sent to the adsorption bed for desorption and regeneration of activated carbon. In this way, the heat energy required for combustion and desorption can be met to save energy. The regenerated activated carbon can be used for the next adsorption.? RCO organic waste gas catalytic combustion equipment uses catalytic combustion method to convert toxic and harmful organic gas into non-toxic gas.? The main structure of RCO organic waste gas catalytic combustion equipment is composed of three major parts: purification device host, induced draft fan and control system. The catalytic combustion purification device includes: dedusting flame arrester, heat exchanger, preheater and catalytic combustion chamber. The organic waste gas enters the preprocessor from the air inlet at the upper part of the equipment, passes through the coarse filter element composed of multi-layer stainless steel wire mesh to remove dust and other particles in the waste gas, and enters the combined adsorption bed from the main channel at the lower part of the device (two rows in parallel with six grids). Each adsorption bed is equipped with a set of pneumatic switch valve, which can change the adsorption bed into adsorption/desorption state. The longitudinal section of the adsorption bed from bottom to top is respectively the inlet manifold, adsorption chamber, air purification chamber and outlet manifold. The adsorption chamber and the air purification chamber are separated by a flower plate, under which a number of adsorption cylinders are hoisted. The waste gas entering the adsorption chamber passes through the adsorption layer through the outer wall of the adsorption cylinder, VOCs are adsorbed by a large number of microporous surfaces of the adsorbent, and the waste gas is purified and then enters the air purification chamber upward through the flower plate holes, Then it enters the main outlet pipe through the switching valve and is discharged by the fan. One of the six adsorption chambers must be in the desorption state, and the other five must be in the adsorption state. Generally, the desorption time is 12 minutes, that is, the adsorption bed responsible for the adsorption work can be desorbed and regenerated once every hour. This work process of the device coincides with the name of the invention zhuanli - a kind of compartment offline desorption bag type adsorption equipment. Its process principle is the same as that of the pulse reverse blow compartment offline bag type dust collector, except that the purification process of the device is "physical adsorption", The bag filter purification process is "physical filtration". The desorption working medium of the adsorption bed is hot air, which is provided by the catalytic combustion device. Generally, the temperature of the hot air is ≤ 150 ℃, which is determined by the boiling point of different VOCs and the saturated vapor partial pressure at the desorption temperature.
What are the common faults of microwave and ultraviolet water treatment equipment, new type Microwave liquid sterilization Leakage in the water pressure drop equipment system, lack of pressure at the inlet of the high-pressure pump, air leakage, water leakage, blockage of the filter element of the precision filter, high-pressure pump fault, etc. may cause the water pressure drop of the equipment. Solution: Overhaul the high-pressure pump and precision filter, and eliminate problems. Microwave liquid sterilization manufactor The increase of equipment water pressure may be due to the error of high-pressure pump outlet scheduling index and the blockage of the pipeline from high-pressure pump to reverse osmosis equipment. Solution: recover the equipment pressure by dispatching the outlet index of the high-pressure pump and cleaning the pipeline between the high-pressure pump and the reverse osmosis equipment. The decrease in water production of the manufacturers of microwave and ultraviolet water treatment equipment may be due to the lower water temperature, lower water pressure, and pollution and blockage of the reverse osmosis membrane. Solution: recover normal production by adjusting the temperature of raw water and cleaning and replacing the reverse osmosis membrane.
The technology of microwave ultraviolet water treatment equipment is to use double layer ultrafiltration membrane for microwave ultraviolet water treatment equipment, or combine ultrafiltration membrane and reverse osmosis filtration membrane for application. Microwave liquid sterilization manufactor When the manufacturer of microwave ultraviolet water treatment equipment applies external pressure on the concentrated solution side, the penetration speed will decrease. When the pressure increases to a certain value, the penetration process will stop and the so-called penetration balance will be reached. The external pressure under the balance condition is called the penetration pressure. When the pressure on the concentrated solution side continues to increase, that is, when the applied pressure is greater than the penetration pressure, The solvent of purified water equipment will reverse its original soaking direction and enter the dilute solution side from the concentrated solution side through the semi permeable membrane, new type Microwave liquid sterilization This phenomenon is called reverse osmosis. For a long time, it will not only affect the effluent quality of the equipment, but also lead to the fouling of the reverse osmosis membrane of the main components of the equipment, resulting in the small output of the pure water equipment, the substandard effluent quality, or the equipment can not be used. In order to ensure the continuous and safe operation of pure water equipment, the maintenance of pure water equipment is very important.
When installing microwave and ultraviolet water treatment equipment, the command must be strengthened to prevent equipment collision. new type Microwave liquid sterilization And these important devices are assigned special management, storage and storage problems. Microwave liquid sterilization manufactor In the field of construction, prepare sufficient quantity and quality of fire-fighting tools for inspection, and require them to use only in case of fire. The construction personnel entering the site shall be checked and wear qualified protective equipment, such as safety helmet, because personal safety is very important.
Have you ever thought about whether you need a sterilizer on your water tank? If so, which Z is better? An aquarium scientist's differences between ozone and ultraviolet sterilizers. Ozone is a gas composed of three oxygen atoms, while the oxygen we breathe is composed of two oxygen atoms. This chemical structure makes ozone highly active, new type Microwave liquid sterilization That's why it's such a powerful sterilizer. Microwave liquid sterilization manufactor It is meaningful that the bulb in the UV germicidal lamp is made of quartz, because quartz will not filter out the UV rays. However, water filters light according to its depth. Therefore, the water flow space between the quartz bulb and the external glass or plastic tube is usually only a few millimeters - a thicker space will reduce the intensity of ultraviolet rays and allow bacteria and other microorganisms to survive.
After years of development, microwave electrodeless UV sterilization equipment has been widely used in drinking water, food, beverages, electronic products, chemicals, medicine, sewage microwave UV water treatment equipment and other fields. Microwave liquid sterilization manufactor High intensity odorless UV germicidal lamp is used to simplify the special stainless steel inner wall, so that the pretreated water has enough UV when passing through the UV. new type Microwave liquid sterilization Irradiation has good sterilization effect. In addition, it has the advantages of simplicity, convenience, broad-spectrum, no secondary pollution, convenient management and automation.