Price of fire fighting integrated pump unit supplied by Jiyuan

2020-09-22
 Price of fire fighting integrated pump unit supplied by Jiyuan

supply Fire fighting integrated pump set As the underground installation is adopted, it can be directly installed around the residential area, and because of its small floor area, the characteristics of the whole underground installation will not affect the lives of residents. The harmony and unity with the surrounding environment can be achieved through the landscape control room above the ground. Fire fighting integrated pump set Price It is used in places that cannot rely on gravity to discharge sewage by itself. Waste water below the water level of the waterway is collected through the sewage tank, as well as waste water discharged far away from the municipal sewage pipe network and sanitary facilities, and sewage is transported to the sewage pipe network with the help of the sewage pump.

 Price of fire fighting integrated pump set supplied by Jiyuan

1、 Fire fighting integrated pump set Price Location selection. supply Fire fighting integrated pump set It is the core part of the water supply and fire fighting pipe network of the whole building or the whole community, plant area. The location of the pump room should be selected not only to facilitate the laying of the water supply and fire fighting pipe network, but also not to have noise impact on rooms with quiet requirements. It should also try to minimize the occupancy of valuable buildings (such as shops and parking spaces). The domestic water supply pump room and fire pump room should be built together, which can not only save land, but also facilitate maintenance management. For a residential area, the pump room is often designed in the equipment room of the underground garage, and is combined with the generator room and other electrical and air-conditioning rooms in the same fire compartment. And the pump room should be as close as possible to the middle of the large water users or the whole community, which can reduce the length of the main pipe and reduce the head loss of the pipe network. The outlet of the pump room shall be directly connected to the outdoor or the emergency exit. If the pump house is located in a civil building, it should not be adjacent to the neighbor's house or on its upper or lower floors, and the pump house should be located in a well ventilated room without freezing. The size of the pump room is determined by the layout of the living pool, fire pool and pump set.

 Price of fire fighting integrated pump unit supplied by Jiyuan

1. To ensure the safety of the pump room, the pump room must be locked. 2、 Fire fighting integrated pump set Price Safety Operation Regulations, Hygiene and Safety Management System for Secondary Water Supply, Patrol Inspection Specifications, Water Quality Inspection Record System must be posted inside. 3 supply Fire fighting integrated pump set There must be the following record documents inside: Patrol Inspection Record, Water Tank Blowdown Record, Disinfection Record, Water Quality Inspection Record. 4. The pump room must be marked with the pressurized area, and the corresponding control system should also be marked with the pressurized area: low area, middle area, high area, etc, Mark the product model, qualified number, ex factory date, etc. 6. Water pump identification: the number of pumps must be painted on each pump; For example: 1 # pump, 2 # pump, 3 # pump, 4 # pump, 5 # pump, words. 7. "Normally open" signboard of inlet and outlet valves; 8. The pipe shall be marked with water flow direction arrow; 9. The prefabricated energy-saving pump room needs a drainage system 10. The energy-saving pump room can realize on-site control and remote monitoring;

 Price of fire fighting integrated pump unit supplied by Jiyuan

supply Fire fighting integrated pump set It is an important water conservancy equipment in urban infrastructure construction, Fire fighting integrated pump set Price It is mainly used for municipal drainage, flood control and waterlogging drainage in flood season, and can be divided into sewage lift pump station and rainwater lift pump station according to the action objects. It is generally installed underground and connected with the urban underground sewage pipe network to collect domestic sewage and rainwater. It is a new environment-friendly pump station. After the mixing treatment, the water level is raised by pressurizing the water pump, and the sewage is transported to the sewage treatment plant, realizing the rapid discharge and treatment of urban sewage.

 Price of fire fighting integrated pump unit supplied by Jiyuan

supply Fire fighting integrated pump set Noise includes pump noise, motor noise and pipeline noise. There is no staff in the assembled pump room during the normal operation of the pump, so the main purpose is to protect the residents around the pump room from being affected. The pump house is mostly used in the basement of residential buildings, Fire fighting integrated pump set Price During operation, the vibration noise of the pump unit spreads along the floor and wall to the upstairs, resulting in obvious vibration of the wall, floor, ceiling and column head of the owner's room upstairs. The room buzz has a serious impact on the human body. Many cities in the north need heating in winter, so many communities have set up heating pump rooms. Ventilation and heat dissipation are required in the pump room, and sound leakage is serious when the pump is running. There will be a high noise sound pressure level outside the pump room, which will seriously affect the quality of life and sleep of residents in the community.