Price of Xinxiang large-scale integrated transmission and distribution pump set

2020-09-30
 Price of Xinxiang large-scale integrated transmission and distribution pump set

large Integrated transmission and distribution pump set While making outstanding contributions to sewage collection and treatment and flood prevention and drainage, it also has many defects, such as large floor area, high cost, and easy to produce methane volatilization to pollute the environment. But with the upgrading of technology, Integrated transmission and distribution pump set Price According to the market demand, we have developed and produced an integrated prefabricated pump station with more optimized performance, which has solved many disadvantages of the concrete pump station and replaced the traditional concrete pump station as the current mainstream pump station.

 Price of Xinxiang large-scale integrated transmission and distribution pump set

large Integrated transmission and distribution pump set In the design, there is no such statement as main pump and standby pump. Our statement is that one is in use and one is standby or two is in use and one is standby. They are standby for each other and used in turn. When one is running, the other is the standby pump. Integrated transmission and distribution pump set Price The first reason for setting a standby pump is to ensure that when the pump is damaged or overhauled, there is still a pump that can work, rather than that we can't use water as long as the pump is broken or regularly overhauled. The second is to let the pump take turns to rest after working for a period of time. To prevent long-term continuous operation from affecting the normal service life of the pump.

 Price of Xinxiang large-scale integrated transmission and distribution pump set

In recent years, with the construction of more and more pump houses around the country, problems related to them have become increasingly apparent, Integrated transmission and distribution pump set Price Management and maintenance, water pollution, safety management and other issues are gradually exposed. How to further strengthen the management level of the above pump room facilities and equipment, further improve and ensure the safe water supply capacity, and manage and maintain all kinds of facilities and equipment in the pump room has become the common concern and work direction of all major water supply management enterprises and water supply equipment manufacturers. Standardized standard pump room construction and management introduced, large Integrated transmission and distribution pump set Mainly based on the optimized configuration and construction of various facilities and equipment in the pump room, the computer network information technology is used to organically integrate various nodes in the pump room. At the same time, in combination with the local economic construction level, according to the actual situation and budget needs of the project, a reasonable standardized construction, management and maintenance scheme is provided and implemented for various pump rooms. Its core is the safe full frequency conversion control pressurization equipment, followed by the integration of computer network information system, and the safety management and maintenance of the whole life cycle.

 Price of Xinxiang large-scale integrated transmission and distribution pump set

Integrated transmission and distribution pump set Price General provisions: equipment discharging heat, steam or harmful substances, large Integrated transmission and distribution pump set Local exhaust should be adopted. When local ventilation can not be used or local ventilation can not meet the health requirements, it shall be supplemented with all-round ventilation or adopt all-round ventilation. The air distribution design shall be optimized according to the characteristics and changes of pollutants, and the normal operation of local exhaust system shall not be damaged. At the same time, when releasing waste heat, moisture and harmful substances, the ventilation volume in all aspects shall be determined according to the large air volume required. When the quantity of harmful substances cannot be determined, the ventilation volume in all aspects can be determined according to the ventilation frequency. All kinds of pump rooms in the domestic sewage treatment station should adopt natural ventilation. When mechanical ventilation is adopted, indoor air should not be recycled. All pump rooms in the oily sewage treatment station should adopt natural ventilation. When mechanical ventilation is adopted, indoor air should not be recycled, and the ventilator and motor should be explosion-proof and directly connected.

 Price of Xinxiang large-scale integrated transmission and distribution pump set

large Integrated transmission and distribution pump set Noise includes pump noise, motor noise and pipeline noise. There is no staff in the assembled pump room during the normal operation of the pump, so the main purpose is to protect the residents around the pump room from being affected. The pump house is mostly used in the basement of residential buildings, Integrated transmission and distribution pump set Price During operation, the vibration noise of the pump unit spreads along the floor and wall to the upstairs, resulting in obvious vibration of the wall, floor, ceiling and column head of the owner's room upstairs. The room buzz has a serious impact on the human body. Many cities in the north need heating in winter, so many communities have set up heating pump rooms. Ventilation and heat dissipation are required in the pump room, and sound leakage is serious when the pump is running. There will be a high noise sound pressure level outside the pump room, which will seriously affect the quality of life and sleep of residents in the community.

 Price of Xinxiang large-scale integrated transmission and distribution pump set

large Integrated transmission and distribution pump set Explain the structure of the integrated prefabricated pump station: 1. Outdoor stainless steel control cabinet: manual and automatic. The following control functions can be realized: (1) Daily automatic position, realizing unattended pump station. (2) Two for use and one for standby, mutual standby, automatic switching, high water level working at the same time, automatic fault switching. 2. Crushing grid: the crushing grid is placed at the inlet of the FRP cylinder of the pump station, and the submersible crushing grid is safe and reliable; The supporting guide rail is convenient for maintenance and overhaul. 3. Liquid level sensor: pressure sensor (standard configuration)/floating ball switch/water level electrode is used, and special monitoring relay is provided to realize automatic control operation of pump station liquid level. four Integrated transmission and distribution pump set Price Service platform: built-in service platform for valve and water pump maintenance; Customize platforms in different forms, locations and heights as required.