Fire fighting integrated pump set Price It is a new electromechanical integrated water supply equipment composed of computer technology, frequency conversion technology and motor pump, to meet the requirements of urban water supply network that water pumping does not produce negative pressure, but also has a certain capacity of regulation and storage, and water supply is cut off during peak periods. Scope of application of integrated pump set: 1. Scope of application: it is applicable to pressurized water supply in areas with sufficient urban pipe network pressure. 2. Applicable project type: large intermediate booster pump station for production and domestic water of industrial and mining enterprises, and water supply of waterworks. 3、 recommend Fire fighting integrated pump set Applicable project position: water supply secondary pressurization system. 4. Other scope of application: domestic water for new, reconstructed and expanded residential buildings, office buildings, hotels, restaurants and other public buildings. 5. Type of using unit: design unit, construction unit and supervision unit.
recommend Fire fighting integrated pump set How to choose? Fire fighting integrated pump set Price The main equipment in the pump station selected according to the input and output are: various controllable valves, pump sets, grid systems, water level gauges, flow meters, etc. According to the requirements of the system and the different control methods adopted, as well as the nature, parameters and characteristics of the input and output signals, the appropriate PLC system can be flexibly selected. Select according to the storage capacity Calculate the actual capacity demand of the storage according to the number of nodes required for programming. The PLC control system used in the current pump station is selected according to the communication requirements, which is generally divided into equipment unit layer, pump station layer, dispatching layer, etc. Layers directly need to transmit various parameter information, so we should select the appropriate PLC equipment according to the field needs, such as network, expansion, off the shelf bus connection, investment and our own equipment.
recommend Fire fighting integrated pump set Look at the trend of future architectural situation? Fire fighting integrated pump set Price Let's talk about it: the house is a place for people to shelter from wind and rain at the beginning, but with the development of society and the improvement of living standards, people continue to pursue a comfortable living environment. While improving the construction level, they install various heating and cooling equipment to solve the problem of heating and cooling, and install fresh air and humidity control equipment to solve the problem of indoor ventilation and humidity. At present, the comfort of the house has reached the standard of constant temperature, humidity, oxygen and cleanliness. However, the energy consumption of buildings has been increasing, accounting for 30-40% of the total energy consumption of the society, resulting in an energy crisis, and the environment is getting worse and worse, which seriously affects the sustainable development of society. How can we not only meet the requirements of living comfort today, but also fundamentally reduce energy consumption? This is a subject that has been studied all over the world.
Fire fighting integrated pump set Price General provisions: equipment discharging heat, steam or harmful substances, recommend Fire fighting integrated pump set Local exhaust should be adopted. When local ventilation can not be used or local ventilation can not meet the health requirements, it shall be supplemented with all-round ventilation or adopt all-round ventilation. The air distribution design shall be optimized according to the characteristics and changes of pollutants, and the normal operation of local exhaust system shall not be damaged. At the same time, when releasing waste heat, moisture and harmful substances, the ventilation volume in all aspects shall be determined according to the large air volume required. When the quantity of harmful substances cannot be determined, the ventilation volume in all aspects can be determined according to the ventilation frequency. All kinds of pump rooms in the domestic sewage treatment station should adopt natural ventilation. When mechanical ventilation is adopted, indoor air should not be recycled. All pump rooms in the oily sewage treatment station should adopt natural ventilation. When mechanical ventilation is adopted, indoor air should not be recycled, and the ventilator and motor should be explosion-proof and directly connected.