The microwave electrodeless ultraviolet sterilization equipment can ensure the sterilization effect and water quality of the effluent. It is a durable and effective sterilization technology. There is no reactivation reaction and no rebound of bacteria, ensuring complete disinfection effect and water quality safety. Compared with other sterilization methods, UV has many obvious advantages, Customized Breeding sterilization and disinfection equipment In particular, unlike chemical fungicides, the ultraviolet sterilizer will not bring toxic substances and residual substances into purified water, Breeding sterilization and disinfection equipment manufactor The chemical composition, odor and pH value of the fluid will not be changed. This feature is very important in pharmaceutical industry and related industries. The chemical dosage of influent can often change the characteristics of products.

When choosing microwave electrodeless ultraviolet sterilization equipment, there are different wave bands to choose from, Customized Breeding sterilization and disinfection equipment It is recommended to select disinfector with deep ultraviolet wave band. Because the deep ultraviolet wave band has a wider sterilization range and stronger sterilization ability. Breeding sterilization and disinfection equipment manufactor In addition, when using the disinfector in the deep ultraviolet wave band, we must pay attention to the radiation dose and time. If the irradiation dose is not enough or the time is too short, there is no way to achieve the expected sterilization effect.

What are the common faults of microwave and ultraviolet water treatment equipment, Customized Breeding sterilization and disinfection equipment Leakage in the water pressure drop equipment system, lack of pressure at the inlet of the high-pressure pump, air leakage, water leakage, blockage of the filter element of the precision filter, high-pressure pump fault, etc. may cause the water pressure drop of the equipment. Solution: Overhaul the high-pressure pump and precision filter, and eliminate problems. Breeding sterilization and disinfection equipment manufactor The increase of equipment water pressure may be due to the error of high-pressure pump outlet scheduling index and the blockage of the pipeline from high-pressure pump to reverse osmosis equipment. Solution: recover the equipment pressure by dispatching the outlet index of the high-pressure pump and cleaning the pipeline between the high-pressure pump and the reverse osmosis equipment. The decrease in water production of the manufacturers of microwave and ultraviolet water treatment equipment may be due to the lower water temperature, lower water pressure, and pollution and blockage of the reverse osmosis membrane. Solution: recover normal production by adjusting the temperature of raw water and cleaning and replacing the reverse osmosis membrane.

When installing microwave and ultraviolet water treatment equipment, the command must be strengthened to prevent equipment collision. Customized Breeding sterilization and disinfection equipment And these important devices are assigned special management, storage and storage problems. Breeding sterilization and disinfection equipment manufactor In the field of construction, prepare sufficient quantity and quality of fire-fighting tools for inspection, and require them to use only in case of fire. The construction personnel entering the site shall be checked and wear qualified protective equipment, such as safety helmet, because personal safety is very important.

To solve the problem of light reactivation: open the channel to realize underground water outflow, to avoid or reduce the visibility of treated water before entering the pipeline. At the same time, use a dark container containing a sample of test water, Customized Breeding sterilization and disinfection equipment It shall be sent for inspection in time to avoid factors such as storage conditions or test time affecting the test results. Improve the light transmittance: adjust the front-end treatment process to reduce the SS mass concentration of water in the UV disinfection device, Breeding sterilization and disinfection equipment manufactor The ultraviolet disinfection I was adjusted to ozone decolorization, which reduced the chromaticity of the influent water to ensure that SS was controlled below 10 mg/L; The front-end technology has been adjusted to strictly control the consumption of PAM and other chemicals, and a defoaming device has been installed at the water inlet of the external disinfection device to reduce the foam content in the water body and increase the light transmittance of the water body.

The power supply is the foundation and should be used carefully. Generally, it needs to work under 200V/50Hz AC power, Customized Breeding sterilization and disinfection equipment In order to ensure the correct operation of the complete set of automatic water softening device. Breeding sterilization and disinfection equipment manufactor The manufacturer of the microwave and ultraviolet water treatment equipment shall ensure that the power cannot be cut off, and that the switch of the equipment cannot be cut to the point, so as to prevent the quality problems of the softening microwave and ultraviolet water treatment equipment and the increase of equipment loss.