The microwave ultraviolet water treatment equipment uses quartz sand filter material to remove the suspended solids, sediment, impurities, etc. of larger particles in the raw water and the turbidity of precipitation. In addition, it can also remove many organic substances, bacteria, x, etc. in the water with the decrease of turbidity, and create a good condition for disinfection after filtration. new type Microwave liquid sterilization Use the adsorption capacity of activated carbon to effectively adsorb organic matter, free residual chlorine, colloid, particles, microorganisms Microwave liquid sterilization programme For some metal ions and decolorization, the exchange function of ion resin is used to remove calcium and magnesium ions in raw water to avoid the impact of scaling on subsequent equipment. However, the operation is laborious and material consuming. Now, the dosing system is used to directly add scale inhibitor.

working principle: The thermal storage catalytic combustion equipment uses natural gas to directly burn organic waste gas. Under the temperature of 750~850 ℃, organic molecules are decomposed into CO2 and H2O. The burned flue gas accumulates heat in the ceramic through the thermal storage ceramic brick, preheats the organic waste gas, and then discharges it. The inlet and outlet directions of the waste gas are automatically switched by the switch valve, and work circularly, RTO can fully recover and burn organic decomposition heat energy, which greatly reduces the energy consumption of the system. Catalytic combustion equipment is applicable to industries: Applicable to the treatment of mixed combustible organic waste gas and odor with large and medium concentration (thousands of ppm) and medium air volume Applicable to waste gas treatment in paint shop Applicable to waste gas treatment of electronic product manufacturing and integrated circuit Applicable to waste gas treatment in printing process and injection molding process Applicable to the treatment of organic waste gas generated in petrochemical, medical and other industries Technical features of regenerative catalytic combustion equipment: Wide range of exhaust gas; High waste gas treatment efficiency; Less maintenance work, safe and reliable; Low pressure loss and high purification efficiency; Long service life of equipment; Low operation cost

According to different lamp tubes, ultraviolet sterilization lamps have thermal cathode low-pressure mercury vapor discharge lamps and cathode low-pressure mercury vapor discharge lamps; The hot cathode low-pressure mercury vapor discharge lamps can be divided into straight type, H-type, U-type tube, etc. from the appearance; new type Microwave liquid sterilization For different needs, it can be divided into low (no ozone), ozone, high ozone, etc. The portable microwave electrodeless ultraviolet sterilization equipment can be used for close mobile irradiation, and the ultraviolet lamp suspension irradiation can also be used. Small articles can be irradiated in the ultraviolet disinfection box. Different kinds of microorganisms have different sensitivity to ultraviolet rays. When using ultraviolet rays for disinfection, the radiation dose must be used to reach the radiation dose required to kill the target microorganisms. Microwave liquid sterilization programme The product of the irradiation intensity and irradiation time of the ultraviolet lamp used for irradiation dose at the surface of the irradiated object. Therefore, according to the irradiation intensity of the ultraviolet light source, the required irradiation time can be calculated.

1. If linear installation is required, please use the installation method of low water inlet and high water outlet to slow down the water flow rate and increase the effect of ultraviolet radiation. 2. When working, Microwave liquid sterilization programme Do not look directly into your eyes with an ultraviolet lamp. When the equipment is open, repeated opening and closing will seriously affect the service life of the lamp. 3. If the water flow is too fast, please install current limiting and pressure limiting devices. 4. If the turbidity of raw water exceeds 5 degrees, a prefilter should be installed to ensure ultraviolet sterilization. 5. Please take out the quartz sleeve every time. new type Microwave liquid sterilization After using the disinfection lamp for two to three months, check the surface for dirt to determine the next time to clean the surface of the quartz sleeve.

Activated carbon adsorption and catalytic combustion equipment is a common volatile organic waste gas treatment equipment. It is energy-saving, environmental protection, no secondary pollution, and high purification efficiency. It is a very good equipment for VOC waste gas treatment. Generally, the main composition of activated carbon adsorption catalytic combustion equipment is as follows: Pretreatment equipment: since honeycomb activated carbon adsorption requires specific conditions such as temperature, humidity and cleanliness, it is necessary to treat the organic waste gas with different characteristics before entering the activated carbon adsorption. The organic waste gas containing more dust particles needs to be filtered. The waste gas with a temperature greater than 45 ℃ needs to be cooled, and the waste gas containing a large number of water mist particles needs to be separated and filtered. Activated carbon adsorption bed: it can absorb organic waste gas by taking advantage of the porous physical characteristics of activated carbon. The design of the adsorption bed follows the law of two-phase adsorption curve. Only by combining the amount of activated carbon and calculating the cross section wind speed and retention time of activated carbon adsorption can the adsorption efficiency meet the design requirements and meet the emission standards. The box is in negative pressure state during equipment operation, and it is required to be air tight. The desorption temperature of the box is between 70-100 ℃ during the desorption process, and the heat preservation is generally 50mm considering the energy saving and safety factors. Ensure that the temperature of the outer wall of the box is not higher than the normal temperature by 15 ℃. Main exhaust fan: as the main power of the equipment, the exhaust fan guides the air to move according to the specified process. The fan can be selected accurately only when it is stable and reliable, and the resistance calculation of the system is accurate. The operation of the fan will produce noise, and the high-power fan needs to be equipped with a sound insulation room. Attention shall be paid to the design that the wind speed at the air outlet shall not be too high. Catalytic combustion equipment: after the system has operated for a period of time, the activated carbon needs to be regenerated after adsorption saturation to restore the adsorption activity of the activated carbon. The organic waste gas is concentrated in the activated carbon. After the organic matter is separated from the activated carbon layer at low temperature, it is decomposed into water and carbon dioxide at about 300 ℃ through the action of catalyst. At the same time, the energy is released. The energy is replaced by the heat exchange device to maintain the energy of spontaneous combustion of the equipment. For a single activated carbon adsorption bed, the desorption time is 2-2.5 hours. The set time of activated carbon adsorption box is automatically switched to desorption regularly. The service life of the ceramic honeycomb noble metal catalyst loaded inside is 8000 hours. The whole desorption system adopts multi-point temperature control to ensure the stability of desorption effect. The selection of organic waste gas catalyst is the core of this equipment. Valve switching system: valves include adsorption system valve, desorption system valve, cooling and emergency discharge valve. The three types of valves are required to be timely and accordingly to ensure that the air leakage rate is less than 2%. The conventional galvanized sheet air valve in the market has air leakage due to unreliable sealing, so it is necessary to select the high temperature resistant air valve with silicone gasket. The temperature is reliable when opening and closing the valve. Due to the temperature of the gas through which the valve passes, it is very easy for conventional plastic electric actuators to age and deform, resulting in ineffective execution. Generally, long rod actuators are used.