recommend Integrated sewage pump set It is a new type of sewage and rainwater integrated automatic collection and lifting system, Integrated sewage pump set Manufacturer It is an integrated pump station in a sense. The barrel body of the pump station is made of advanced materials, such as reinforced glass fiber or polyethylene resin for automatic casting. The internal water pump, pipeline, valve, instrument, control equipment, ladder and other accessories required by the user can be provided by Philippine Source in a complete set and delivered after installation and commissioning. He can even bring maintenance room and power grid, which is a new kind of integrated pump station equipment, easy to use, reliable quality, less civil work and low cost. High integration and volume optimization are the remarkable characteristics of the pump station, which are the substitutes for the traditional small and medium-sized concrete pump stations.

recommend Integrated sewage pump set As the underground installation is adopted, it can be directly installed around the residential area, and because of its small floor area, the characteristics of the whole underground installation will not affect the lives of residents. The harmony and unity with the surrounding environment can be achieved through the landscape control room above the ground. Integrated sewage pump set Manufacturer It is used in places that cannot rely on gravity to discharge sewage by itself. Waste water below the water level of the waterway is collected through the sewage tank, as well as waste water discharged far away from the municipal sewage pipe network and sanitary facilities, and sewage is transported to the sewage pipe network with the help of the sewage pump.

Integrated sewage pump set Manufacturer Introduce the basic structure of the integrated pump station: 1 recommend Integrated sewage pump set The GRP glass fiber reinforced plastic cylinder is made of GRP glass fiber reinforced plastic, and the process is continuous mechanical winding. It is characterized by firmness, durability, non leakage, corrosion resistance, and a service life of 50 years. 2. The base is made of GRP glass fiber reinforced plastic, and the process is molding. It is characterized by anti clogging, anti floating and anti sinking, and its service life can also reach 50 years. 3. The top cover is generally made of embossed aluminum plate, or stainless steel, glass fiber reinforced plastic and other materials, which is used for personnel access. 4. Handrails are made of 304 stainless steel or 316 stainless steel. 5. The control cabinet can be made of 304 stainless steel or 316 stainless steel, which is the core of intelligent control. 6. The flange is made of 304 stainless steel. 7. Check valve, with various stainless steel materials, such as 304, 201, 316, etc. 8. Gate valve is made of 304 stainless steel, or 201, 316, etc. 9. The grating support is made of 304 stainless steel. Similarly, 316 stainless steel can also be selected.

recommend Integrated sewage pump set Explain the structure of the integrated prefabricated pump station: 1. Outdoor stainless steel control cabinet: manual and automatic. The following control functions can be realized: (1) Daily automatic position, realizing unattended pump station. (2) Two for use and one for standby, mutual standby, automatic switching, high water level working at the same time, automatic fault switching. 2. Crushing grid: the crushing grid is placed at the inlet of the FRP cylinder of the pump station, and the submersible crushing grid is safe and reliable; The supporting guide rail is convenient for maintenance and overhaul. 3. Liquid level sensor: pressure sensor (standard configuration)/floating ball switch/water level electrode is used, and special monitoring relay is provided to realize automatic control operation of pump station liquid level. four Integrated sewage pump set Manufacturer Service platform: built-in service platform for valve and water pump maintenance; Customize platforms in different forms, locations and heights as required.

recommend Integrated sewage pump set Noise includes pump noise, motor noise and pipeline noise. There is no staff in the assembled pump room during the normal operation of the pump, so the main purpose is to protect the residents around the pump room from being affected. The pump house is mostly used in the basement of residential buildings, Integrated sewage pump set Manufacturer During operation, the vibration noise of the pump unit spreads along the floor and wall to the upstairs, resulting in obvious vibration of the wall, floor, ceiling and column head of the owner's room upstairs. The room buzz has a serious impact on the human body. Many cities in the north need heating in winter, so many communities have set up heating pump rooms. Ventilation and heat dissipation are required in the pump room, and sound leakage is serious when the pump is running. There will be a high noise sound pressure level outside the pump room, which will seriously affect the quality of life and sleep of residents in the community.

1、 Integrated sewage pump set Manufacturer Location selection. recommend Integrated sewage pump set It is the core part of the water supply and fire fighting pipe network of the whole building or the whole community, the plant area. The location of the pump room should be selected not only to facilitate the laying of water supply and fire fighting pipe network, but also not to have noise impact on rooms with quiet requirements. It should also try to minimize the occupancy of valuable buildings (such as shops and parking spaces). The domestic water supply pump room and fire pump room should be built together, which can not only save land, but also facilitate maintenance management. For a residential area, the pump room is often designed in the equipment room of the underground garage, and is combined with the generator room and other electrical and air-conditioning rooms in the same fire compartment. And the pump room should be as close as possible to the middle of the large water users or the whole community, which can reduce the length of the main pipe and reduce the head loss of the pipe network. The outlet of the pump room shall be directly connected to the outdoor or the emergency exit. If the pump house is located in a civil building, it should not be adjacent to the neighbor's house or on its upper or lower floors, and the pump house should be located in a well ventilated room without freezing. The size of the pump room is determined by the layout of the living pool, fire pool and pump set.