1. To ensure the safety of the pump room, the pump room must be locked. 2、 Assembled machine room manufactor Safety Operation Regulations, Hygiene and Safety Management System for Secondary Water Supply, Patrol Inspection Specifications, Water Quality Inspection Record System must be posted inside. 3 supply Assembled machine room There must be the following record documents inside: Patrol Inspection Record, Water Tank Blowdown Record, Disinfection Record, Water Quality Inspection Record. 4. The pump room must be marked with the pressurized area, and the corresponding control system should also be marked with the pressurized area: low area, middle area, high area, etc, Mark the product model, qualified number, ex factory date, etc. 6. Water pump identification: the number of pumps must be painted on each pump; For example: 1 # pump, 2 # pump, 3 # pump, 4 # pump, 5 # pump, words. 7. "Normally open" signboard of inlet and outlet valves; 8. The pipe shall be marked with water flow direction arrow; 9. The prefabricated energy-saving pump room needs a drainage system 10. The energy-saving pump room can realize on-site control and remote monitoring;
Assembled machine room manufactor It is a new electromechanical integrated water supply equipment composed of computer technology, frequency conversion technology and motor pump, to meet the requirements of urban water supply network that water pumping does not produce negative pressure, but also has a certain capacity of regulation and storage, and water supply is cut off during peak periods. Scope of application of integrated pump set: 1. Scope of application: it is applicable to pressurized water supply in areas with sufficient urban pipe network pressure. 2. Applicable project type: large intermediate booster pump station for production and domestic water of industrial and mining enterprises, and water supply of waterworks. 3、 supply Assembled machine room Applicable project position: water supply secondary pressurization system. 4. Other scope of application: domestic water for new, reconstructed and expanded residential buildings, office buildings, hotels, restaurants and other public buildings. 5. Type of using unit: design unit, construction unit and supervision unit.
supply Assembled machine room There were few original cast-in-place operations on the site, and the health did not disturb the residents. From then on, we bid farewell to the "gray and hazy" construction site. In addition, the reuse rate of steel formwork and other materials has been improved, and the waste, loss and energy saving can be reduced by more than half. It can be seen that, Assembled machine room manufactor It makes up for the shortcomings of the existing reinforced concrete operation, and the quality of the houses is also very good, which is acceptable to the public. Think about the future when prefabricated housing becomes the main construction industry in China, there will be no more dust flying around the construction site and no more construction waste everywhere. At present, the environment in our country is getting worse and worse. It can be seen that the energy-saving pump room is not only good, but also very promising.
supply Assembled machine room How to choose? Assembled machine room manufactor The main equipment in the pump station selected according to the input and output are: various controllable valves, pump sets, grid systems, water level gauges, flow meters, etc. According to the requirements of the system and the different control methods adopted, as well as the nature, parameters and characteristics of the input and output signals, the appropriate PLC system can be flexibly selected. Select according to the storage capacity Calculate the actual capacity demand of the storage according to the number of nodes required for programming. The PLC control system used in the current pump station is selected according to the communication requirements, which is generally divided into equipment unit layer, pump station layer, dispatching layer, etc. Layers directly need to transmit various parameter information, so we should select the appropriate PLC equipment according to the field needs, such as network, expansion, off the shelf bus connection, investment and our own equipment.
Users also have this problem again. First of all, we should know the composition of the pump station. ad locum, Assembled machine room manufactor The pump set is divided into three parts. Main body of pump unit, external control equipment and internal equipment. First, we should select the wall thickness of the pump unit cylinder according to the actual demand. The factors to be considered here include: geology, temperature, working environment of pump unit, altitude, etc. Therefore, the selection of pump unit cylinder wall thickness should be summarized and considered. The wall thickness directly affects the firmness of the pump set. Of course, the selection of internal equipment is also important. During this period, the selection of submersible sewage pump is important. Here, the selection of flow head of submersible sewage pump is important. supply Assembled machine room The flow head of submersible sewage pump shall be selected according to the actual situation. There are many types of submersible sewage pumps. For example, 200 in front of 200WQ300-7-15 refers to the diameter, WQ refers to the pump type, and 300 refers to the flow of 300m ³/ h. 7 refers to the lift of 7m, and 15 refers to the power of this submersible pump of 15KW.